Your Canadian project
Office pod dimensions and specifications
Compare exterior size, usable interior, door passage, packaging and ventilation across the six FocusPod models. All dimensions below are metric.
What the measurements describe
Exterior dimensions describe the base pod, not the space needed for assembly, ventilation or door swing. Interior dimensions describe the enclosure before checking the usable layout with furniture. Door passage measurements do not establish an accessible route or an accessibility certification.
Ventilation and electrical figures
The listed airflow is the maximum adjustable ventilation specification. Standard ventilation exchanges air with the surrounding room. Listed standard-system power is not the capacity of the power outlets or a complete installed electrical-load calculation. Confirm requirements for selected equipment and cooling separately.
Use the approved configuration
These base-model figures come from the FocusPod configurator technical record checked for this site. Your final specification must identify any change caused by options, additional packages or custom requests. Use that approved record for freight, site planning and installation.
CAD blocks and project drawings
For a space plan, start with the dimension table below and allow separately for the door swing, ventilation, assembly and access route. If your designer needs an office phone booth CAD block, a furnished plan or another drawing format, send the model, furniture selection and required file format to sales@focuspodcanada.com. The team must confirm whether an appropriate model-specific file is available. This page does not provide a downloadable CAD or BIM library, and the 3D configurator is not a construction drawing.
Fire safety & building requirements
Sprinkler and fire-alarm options are available. We help you confirm the details for your pod and workplace.
Can you include sprinklers and fire alarms?
Yes. Choose the optional sprinkler and fire-alarm combo in the configurator. It is priced per pod and included in your configuration total when selected. Your building manager may request it as part of approving the pod for your space; the equipment, building-system connections and installation scope are confirmed for your site.
What should I know about fire ratings?
Fire information is specific to the model and materials. A material fire classification does not establish a fire-resistance rating for the complete pod. Ask us to confirm the relevant test documentation for your chosen model and finishes.
An acoustic “Class A” rating describes sound reduction, not fire performance.
What should we check before ordering?
Start with your building manager: they may have requirements for introducing a pod into your workplace. Share those requirements and your installation address with us so we can confirm the appropriate equipment and connections with your building team. Local fire requirements still apply; the package is not a blanket requirement for every pod.
| Model | Exterior · W × D × H | Interior · W × D × H | Door passage · W × H | Maximum adjustable airflow | Standard-system power |
|---|---|---|---|---|---|
| Solo | 1100 × 1050 × 2250 mm | 920 × 1010 × 2079 mm | 872 × 2042 mm | 115 m³/h | 50 W |
| Solo Plus | 1600 × 1350 × 2250 mm | 1420 × 1310 × 2079 mm | 872 × 2042 mm | 110 m³/h | 50 W |
| Duo | 1600 × 1350 × 2250 mm | 1420 × 1310 × 2079 mm | 872 × 2042 mm | 110 m³/h | 50 W |
| Team | 2250 × 1050 × 2250 mm | 2070 × 1010 × 2079 mm | 872 × 2042 mm | 110 m³/h | 50 W |
| Meet | 2250 × 1600 × 2250 mm | 2070 × 1560 × 2079 mm | 872 × 2042 mm | 218 m³/h | 100 W |
| Max | 2600 × 2330 × 2250 mm | 2420 × 2290 × 2079 mm | 872 × 2042 mm | 327 m³/h | 160 W |
Base dimensions exclude the clearance needed for assembly, ventilation and door swing. Confirm selected options and site requirements.
A space of your own
Let’s make it yours.
Choose the pod. Shape the details.
We bring your approved configuration together.